Home > Emergency Back-Up Power
Emergency Back-Up Power
Unexpected power outages or failure on the grid level bring severe consequences in industry and commerce. Even grid fluctuations or short circuits can cause crucial electrical components to fail. Emergency power generators fueled by diesel are no longer feasible as backup power systems due to the rising fuel costs, noise pollution, and the impact on the emissions score. As the alternative, HIS Energy offers a safe and reliable source of emergency power with smart HIS-EMS and HISbatt energy storage solutions for industries and businesses.
With our intelligent EMS, any power supply failure from the grid is immediately compensated. The BESS disconnects the load from the grid so that your crucial machines do not experience any interruption. When every second counts, the rapid response capability of lithium batteries enables immediate provision of power.
Microgrid
Battery Energy Storage Systems (BESS) for microgrids are especially beneficial for projects such as construction sites and new apartment complexes where the utility grid connection has yet to be upgraded. Additionally, with increased integration of renewables, EV chargers, and decentralized energy production, BESS can support weak grids to ensure a reliable local power supply in the event of disruptions to the utility grid
Emergency backup power is available for critical loads, peak shaving can be performed for businesses as well as support EV chargers. Find out more about all the applications for HISbatt.
Forecast based Charging
Many grid operators or Distribution Network Operators (DNO’s) limit the maximum PV feed-in power for most residential as well as commercial and industrial PV systems. Consequently, when the PV system produces surplus energy, it must be curtailed and the efficiency of the PV systems as well as their ROI plummets. In such cases, PV system operators can use forecast-based battery charging to generate higher PV yields and utilize the energy produced from PV systems efficiently even during low production hours.
The intelligent HIS Energy Management System calculates the optimal charging and discharging strategy based on past load profiles, PV production profile, weather forecast, battery capacity and battery SoC.
As an example, the HIS EMS recognizes that there are critical loads and peak shaving that occurs during early hours of the day. The battery discharges during these hours and the excess PV energy during the day is used to charge the batteries. The batteries are then discharged, as required, during the evening and night for critical loads, EV charging, or other uses. In this manner, the PV systems operate at maximum efficiency and produce the most energy. The BESS provides peak shaving, reduces consumption from the grid, as well as provides Time of Use applications!
Time of Use
Use HISbatt battery storage solutions to reduce your grid consumption and costs. The battery storage is charged during off-peak hours i.e. when electricity tariffs are low (or even negative). On the other side, as the electricity costs rise i.e. peak tariff, the battery storage discharges to minimize the consumption from the grid. This provides users a reliable and predictable energy source as well as faster amortization of investments.
With HIS Energy Management System, you can go a step further and choose non-critical loads in our HIS Flow Portal. These non-critical loads are switched off or limited during peak tariff. For example, companies can limit on-site EV charging when electricity costs are too high. Instead, the EVs are charged during low tariff periods or through on-site PV generation. A decision tree is defined and management strategies are computed based on user defined time series. Find out more about the possibilities with HIS Energy Management System.
Load and Source Control
Get an overview of all connected sources and loads with the smart and intelligent HIS Energy Management System. The EMS allows you to control the operation of your energy generators through relays or digital switching contacts. You can also disconnect or connect loads in your energy network directly via the HIS Energy Flow portal.
For both sources and loads, you can also set a tolerance time. If the load or source behavior is not within the acceptable thresholds, the digital contacts are triggered and the loads are disconnected.
Are you interested in decreasing your energy costs using Plug & Play energy storage solutions tailored for your business?
Use our quick 5-minute form to get a detailed quote or get into contact with us. Our modular solution fits your project perfectly and offers a wide range of applications.
Get the most from your battery storage
Li-Ion BESS is multi-purpose and generates multiple streams of revenue. Get the most out of your battery storage system for peak shaving by using it to:
- Reduce overall consumption from the grid
- Benefit from fluctuating electricity prices
- Store excess renewable energy
- provide lucrative grid balancing services with battery storage systems.
- Increase independence from the electric grid
- Provide emergency backup power supply (such as UPS),
Peak Shaving
Shave offload peaks for your commercial or industrial business with reliable battery energy storage systems.
PV Self Consumption Optimization
Store excess energy from your solar panels to increase PV self-consumption and decrease dependence on the expensive grid for an efficient power storage system.
E-Mobility
Maximize the revenue from your Fast EV charging infrastructure by integrating smart energy storage solutions.
Emergency / Backup Power
Ensure reliable uninterruptible power supply for your critical sensitive load using our robust BESS solution for energy management system
Time of Use
Use our smart state-of-the-art EMS to optimize energy consumption by charging during off-peak hours.
Multi Use application
Maximize ROI by combining multiple applications, such as PV self-consumption, peak shaving, and forecast-based charging.
Peak Shaving
Shave offload peaks for your commercial or industrial business with reliable battery energy storage systems.
PV Self Consumption Optimization
Store excess energy from your solar panels to increase PV self-consumption and decrease dependence on the expensive grid for an efficient power storage system.
E-Mobility
Maximize the revenue from your Fast EV charging infrastructure by integrating smart energy storage solutions.
Emergency / Backup Power
Ensure reliable uninterruptible power supply for your critical sensitive loads using our robust BESS solutions
Time of Use
Use our smart state-of-the-art EMS to optimize energy consumption by charging during off-peak hours.
Multi Use application
Maximize ROI by combining multiple applications, such as PV self-consumption, peak shaving, and forecast-based charging.
Related Products
Interested in peak shaving and more for your business? Check our Plug-and-Play battery solutions with air and
liquid cooled batteries.
HISbatt-233L
- 92 kVA 233 kWh Plug & Play, All-in-One LFP solution
- IP54 Outdoor enclosure with IP67 battery modules
HISbatt-215A
- 92 kVA 215 kWh Plug & Play, All-in-One LFP solution
- IP54 Outdoor enclosure
Hungry for more information?
Get in touch with our experts through this contact form. If you already have a project in mind, fill out your details for an official quote and book a meeting with our team ASAP!