HIS ENERGY · MODULAR BESS · 800 V AC

HISbatt 418L: modular 800 V battery storage

Start with 418 kWh. Plan expansion around your project.

Liquid-cooled battery storage with a rear-mounted PCS for solar parks, agrivoltaics and commercial energy projects. Choose 210 kVA at 800 V or 690 V, or 125 kVA at 400 V. HIS EMS, controller and commissioning are included.

Request a BESS project assessmentTechnical data · English PDF

No final battery size needed. Share what you already know.

HISbatt 418L battery cabinet with 418 kWh installed energy

418 kWhper cabinet
800 V690 / 400 V alternatives
5 / 10 yearsproduct / capacity warranty*
20–25 weeksindicative delivery*

*Warranty terms apply. The binding delivery schedule is confirmed in the project quotation.

Build the storage capacity your site needs

For PV parks and phased projects

Use cabinet-sized increments to match the initial project requirement and plan future expansion. An 800 V AC interface suits appropriately designed PV busbars and transformer connections. HIS reviews voltage architecture, connection limits and operating strategy with your EPC.

One coordinated system

HIS combines battery storage, PCS, a German-developed EMS and commissioning. For electricity trading, we coordinate operating limits and interfaces with your marketing partner. Market access and settlement are defined separately in the project scope.

Three voltage options, clearly defined

AC voltage Nominal PCS apparent power Installed energy
800 V, three-phase 210 kVA 418 kWh
690 V, three-phase 210 kVA 418 kWh
400 V, three-phase 125 kVA 418 kWh

Model HB-418L-210K-C05-I. Voltage denotes the selected AC interface, not an on-site voltage selector. kVA is apparent power; active power depends on the operating point and reactive-power requirements. Installed energy is not usable AC energy.

From one cabinet to a multi-cabinet system

Cabinets Installed energy Aggregate PCS rating at 800 / 690 V At 400 V
1 418 kWh 210 kVA 125 kVA
2 836 kWh 420 kVA 250 kVA
4 1,672 kWh 840 kVA 500 kVA
5 2,090 kWh 1050 kVA 625 kVA
8 3,344 kWh 1680 kVA 1000 kVA

Multiple cabinets can operate in parallel. HIS coordinates the number of units, communications, protection and electrical infrastructure for the site. Reserve space, cable routes and connection capacity when planning later expansion.

Examples show equipment totals, not guaranteed power at the grid connection or recommended sizing.

Cabinets or a PowerPack 800 V container?

Choose the architecture around the installation and operating plan, then compare the complete installed cost.

Planning priority HISbatt 418L cabinets PowerPack 800 V
Starting capacity 418 kWh increments Larger integrated container configurations
Site layout Individual positions with required service clearances Consolidated 20 ft container arrangement
Auxiliary supply Separate 230 V single-phase supply per cabinet Integrated 800-to-400 V auxiliary transformer
Installation Plan cabinet connections and auxiliary distribution More equipment consolidated within one enclosure
Typical decision Smaller increments and phased investment Larger initial requirement and consolidated integration

Eight cabinets provide 3.344 MWh installed energy. This is a useful comparison point with a fully configured PowerPack, but power ratings, usable energy and installation costs must be compared separately.

Explore PowerPack 800 V →

Plan the auxiliary supply and service space

A separate auxiliary connection is required for every cabinet: 230 V AC single-phase, maximum load 32 A, specified protection 40 A. Average auxiliary demand during operation is up to 2.5 kW; this does not replace sizing for the maximum load.

Your electrical planner must coordinate circuit protection, cable sizing and phase allocation across multiple cabinets.

Battery enclosure: 1,350 × 1,900 × 2,400 mm (W × D × H), plus 400 mm rear PCS projection. Allow at least 1 m maintenance clearance and confirm the final site layout, access and local requirements. Weight: 3,700 kg.

Rear-mounted PCS on the HISbatt 418L cabinet
Rear view: PCS projects beyond the battery enclosure.

What HIS supplies and what we plan together

  • 418 kWh battery cabinet with the selected PCS voltage variant.
  • HIS EMS/controller and commissioning included.
  • 5-year product warranty and 10-year capacity warranty under the applicable terms.
  • Indicative delivery: 20–25 weeks; binding schedule in the quotation.

Civil works, site wiring, auxiliary distribution, transformer, grid protection, plant controller and marketing services are defined in the project quotation. We provide the applicable grid-compliance documentation for the selected variant and project country. Grid-connection approval remains site-specific.

Download current technical data · English PDF

Questions before choosing your battery cabinet

Can I start with one cabinet?

Yes. One cabinet provides 418 kWh installed energy. HIS matches the PCS variant and system integration to your connection and application.

Can cabinets be added later?

Expansion can be planned by adding cabinets. Compatibility, EMS integration, connection capacity and the installation design are checked for the expanded system.

Does the 800 V cabinet supply its own auxiliary power?

No. It requires a separate 230 V single-phase auxiliary connection. PowerPack 800 V containers include an 800-to-400 V auxiliary transformer.

Is the 400 V version also 210 kVA?

No. The 400 V option is rated at 125 kVA. The 800 V and 690 V options are rated at 210 kVA.

Which information is needed for a first assessment?

Share the country, application, known connection voltage, desired capacity or cabinet count and project timing. Unknown technical details can follow later.

Which configuration fits your project?

Send the information you already have. HIS reviews the technical fit, the cabinet-versus-container choice and the next planning steps. A detailed economic study is scoped separately.

Request a HISbatt 418L assessment

Technical details and files are optional. No login or meeting booking required.