BESS references

Battery storage projects delivered across Europe

From compact commercial storage to multi-MWh installations: these anonymised references show different system sizes and applications in Germany, France, Bulgaria and the Netherlands.

We can review your site, load profile and grid connection data to identify a suitable system architecture for your project.

Selected projects

Storage solutions for industry, solar PV and e-mobility

HISbatt battery cabinets at a supermarket in Nice, France

Nice, France · Supermarket

Energy trading and EV charger power boosting

1,165 kWh460 kW

The battery at the supermarket in Nice is used for energy trading and to support the EV charging stations, providing additional charging power for electric vehicles.

Read the Nice case study →
Two installed HISbatt battery cabinets in Germany

Germany

Industrial storage for peak shaving and self-consumption

466 kWh184 kW

Combined peak shaving and optimisation of PV self-consumption.

Modular HISbatt battery installation in Bulgaria

Bulgaria

Multi-MWh BESS for energy trading

3.26 MWh1,370 kW

Modular battery installation for electricity trading.

HISbatt commercial storage with inverters at a German site

Germany

Commercial storage for self-consumption

233 kWh184 kW

AC-coupled storage to increase the use of locally generated energy.

Row of installed HISbatt battery cabinets in the Netherlands

Netherlands

Modular BESS at megawatt-hour scale

1.165 MWh460 kW

Multiple system units to optimise self-consumption at an existing energy site.

Two HISbatt battery cabinets beside charging infrastructure in Germany

Germany

Battery storage for e-mobility

466 kWh184 kW

Battery-supported charging infrastructure to reduce demand on the grid connection and provide additional charging power.

Installed HISbatt battery storage at a German commercial site

Germany

Self-consumption and dynamic electricity tariffs

233 kWh120 kW

Combining self-consumption optimisation with time-dependent energy use.

A process for your project

From application to the right BESS architecture

Project and grid data

Load profile, PV generation, grid connection, voltage, transformer and intended application establish the technical basis.

System design

Power, capacity, C-rate, PCS, EMS and the optional AC/MV scope are coordinated for the project.

Integration and operation

Interfaces, commissioning, monitoring, service and warranty options are defined for the project.

Scalability

HISbatt solutions range from modular commercial storage to combined multi-MWh container systems.

FAQ

Questions about our BESS references

Which applications have been implemented?

The references include peak shaving, self-consumption, energy trading, dynamic electricity tariffs and power support for EV charging.

What project sizes are shown?

The projects shown range from 233 kWh to 3.26 MWh. The appropriate size for a new site depends on its operating goals and grid connection.

Can an existing PV system and grid connection be incorporated?

For retrofit and repowering projects, we review existing transformers, PCS, switchgear, cable routes and grid connection conditions.

How can I start a similar project?

Submit what you already know about your site and objective. Load or generation profiles, grid data and a target power/capacity are helpful but can follow later.

Which reference concept fits your site?

Share your available project and grid data. Our BESS team will assess the appropriate power, capacity and connection architecture.

PV co-location with HISbatt Powerpack 800V

Two project-specific battery architectures combining solar PV and BESS. The information describes the project configuration and planned HIS scope; operating results are not presented here.

HISbatt Powerpack 800V – Project visualisation · Illustrative scene, not a photograph of the project site.
Project visualisation · Illustrative scene, not a photograph of the project site.

Chiemsee, Germany

5.2 MW / 10.868 MWh alongside a 7 MWp PV park

At Chiemsee, the BESS project configuration complements an existing operational 7 MWp PV park. Four 20-foot Powerpack containers are configured for connection to a three-winding transformer.

Container configuration
  • 2 × 1,600 kW / 3,344 kWh
  • 2 × 1,000 kW / 2,090 kWh
HISbatt Powerpack 800V — Illustrative product image — not a photograph of the project site.
Illustrative product image — not a photograph of the project site.

Constanța region, Romania

1.2 MW / 5.016 MWh with project-specific sizing

The PV co-location project in the Constanța region comprises two 800 V Powerpack containers. Power and capacity are tailored to the project requirements and on-site transformers.

Container configuration
  • 1 × 700 kW / 2,926 kWh
  • 1 × 500 kW / 2,090 kWh

HIS project scope

BESS sizing, battery containers with integrated PCS and auxiliary supply, EMS and plant controller/PMS. The project scope also includes commissioning, operation and maintenance (O&M), on-site training, foundation-planning support and coordination of grid-control requirements.

The integrated 800 V / 400 V auxiliary transformer removes the need for an additional external 400 V supply for the Powerpack.

Customers and EPC partners remain anonymous. The services listed describe the project scope and do not confirm completed commissioning.

Share your location, PV capacity and available grid or transformer data. You do not need to know the final battery size yet.